Eurodita Twin Skin two bed log cabin 11x6m

The Eurodita Twin Skin two bed log cabin 11x6m delivers an accommodation project route subject to local-authority review, with thermal specification confirmed at quotation stage.

External size11 x 6m
Wall44-100-44
Storeys1
SupplyKit, EXW Eurodita factory, quoted in writing
Request a quote

Supplied to dealers, developers and private-label partners; larger homes are also supplied directly to private clients.

Technical data sheet

Specification recorded for Eurodita Twin Skin two bed log cabin 11x6m. Dimensions are the building's external dimensions. A row appears only where a figure is recorded for this model.

Building
External dimensions11 x 6 m
External footprint area66 m²
Eaves height220 cm
Ridge height312 cm
Storeys1
BaseExternal footprint 11 x 6 m. Base type and size are confirmed for the specific model and site.
Structure
Wall build-up44-100-44 mm: 44 mm outer skin, 100 mm cavity, 44 mm inner skin. 188 mm total wall thickness.
Other wall optionsThe other approved twin-skin build-ups and solid wall profiles can be specified to suit the project and budget.
ConstructionInterlocking tongue and groove joints
TimberNorthern European timber
Storm brace and anchor setIncluded
Floor
Floor bearersImpregnated as standard
Floor boards28 mm
Roof
Roof boards19 mm tongue and groove boards
Doors and windows
DoorsDouble-Glazed Timber Joinery, Standard Profile
WindowsDouble-Glazed Timber Joinery, Standard Profile
Scope of these figures
InsulationThe 100 mm cavity is the space insulation occupies. Eurodita supplies the structure prepared for insulation, not the insulation material, so the cavity dimension is not an insulation specification.
AvailabilityBuild-up availability and suitability for a given project and destination are confirmed per order.
PerformanceThese dimensions establish no thermal, fire, structural or certification performance.

Download technical data sheet (PDF) Wall profile reference

Add-ons & Customisation

Options for this model (branding, wall thickness, openings, insulation preparation, partitions, veranda) are listed on What is in a Eurodita kit and confirmed per order.

B2B enquiry
Eurodita Twin Skin two bed log cabin 11x6m
44-100-44 · 11 x 6m external · quoted in writing, EXW Eurodita factory
Different size or layout? Send a bespoke brief
Eurodita Twin Skin two bed log cabin 11x6mRequest a quote

Need this in a different size?

This model is supplied as a 11 x 6 m footprint. If your customer needs a different layout, send a drawing. Eurodita will confirm whether the qualified bespoke route and factory scope fit the exact project. Partner branding is agreed per order.

  1. 1 Send a drawing A hand sketch can start the review. Mark known window and door positions, wall thickness and heights; Eurodita confirms any missing technical inputs.
  2. 2 Confirm the quotation scope If the enquiry fits, pricing and any CAD/3D or technical material are prepared to the agreed scope.
  3. 3 Review the agreed scope Revisions follow the quotation and project scope until written sign-off.

CAD/3D quotation material is prepared to the qualified project scope. Availability and timing are confirmed during qualification. Partner branding is applied where agreed; required manufacturer, legal and traceability information is retained.

Send a bespoke brief

Dimensions, wall thickness and opening positions are confirmed per project at quote stage. Bespoke production timing is confirmed at quotation stage. See published projects for built examples with dimensions and drawings, or review the rest of the 2 bedroom log cabins range.

About This Eurodita Twin Skin two bed log cabin 11x6m

Product Overview

The Eurodita Twin Skin two bed log cabin 11x6m delivers an accommodation project route subject to local-authority review, with thermal specification confirmed at quotation stage. This double-wall construction cabin suits extended-season accommodation, managed-site developments, and holiday retreat projects. The twin skin design incorporates insulation between walls for weather-protection details and project comfort review.

Layout & Configuration

The cabin features two separate bedrooms within the 66m² footprint, maximising accommodation density for multi-occupancy requirements. The open-plan living area connects kitchen and lounge spaces efficiently. High eaves at 220cm ensure comfortable headroom throughout, while the configuration accommodates families or project users.

Timber & Construction

Construction utilises Northern European timber with 44-100-44mm twin skin wall build-up, with insulation scope confirmed per quote. The cavity is the space insulation occupies. Eurodita supplies the timber structure prepared for insulation and does not normally supply the insulation materials, so a cavity dimension does not by itself specify insulation. These dimensions do not by themselves establish thermal, fire, structural or project suitability. Interlocking tongue-and-groove joints ensure assembly stability and weather sealing. Double-glazed timber joinery includes standard profile windows and doors throughout, maintaining consistent aesthetic and specification standards across all openings.

Floor & Roof

The floor system incorporates 28mm boards over pressure-treated bearers for moisture resistance and longevity. Roof construction features 19mm tongue-and-groove boards providing structural decking for weather covering. Storm bracing reinforces the structure against wind-exposure requirements reviewed in project documentation, supporting stability in exposed locations across European markets.

Customisation Options

Wall thickness upgrades accommodate enhanced insulation requirements for colder climates. Triple glazing options improve thermal specification further. Additional partition kits enable room reconfiguration, while veranda extensions increase living space. Contractors can specify upgraded joinery profiles and alternative roof coverings to match project requirements and local project requirements.

Manufacturing & Delivery

The Eurodita factory is dimensioned for 150,000 m³ of timber a year. Freight route and final delivery timing are agreed per order in the written quotation. Eurodita standard terms are EXW from the Eurodita factory. The facility accommodates bespoke modifications and project-specific requirements for developers requiring tailored specifications or volume orders.

Private Label Partnership

Private-label manufacturing enables dealers to market cabins under their own branding with customised documentation and specifications. The partnership includes 3D visualisation services, branded assembly guides, and showroom display programmes. Technical support supports partners can confidently specify and sell accommodation cabins projects to their customer base.

What should dealers confirm before quoting Eurodita Twin Skin two bed log cabin 11x6m?

Eurodita supplies Eurodita Twin Skin two bed log cabin 11x6m as a private-label B2B Twin Skin log cabin with a 11 x 6m footprint and a source-listed Twin Skin build-up of 44-100-44mm. Before quoting, dealers should confirm the quote stage package, layout, openings, selected wall or insulation scope, foundation interface, unloading access, EXW release or freight route from the Eurodita factory, private-label documentation, and local-authority planning or site-use review requirements.

Warranty & Support

All structural timber includes ten-year warranty coverage against defects and weather damage. Pressure treatment protects against moisture and pest damage throughout the warranty period. Comprehensive assembly documentation and technical support ensure contractors can complete installation efficiently while maintaining warranty compliance and structural performance.

B2B Order Framework

Scope is confirmed in the written quotation. Details: Reading a Eurodita quotation.

Private-label scope

Branding on packaging and documents, agreed per order.

Production planning

Production scope confirmed in the written quotation.

Commercial terms

Price, quantity and payment quoted per order.

Technical documents

Drawings and specifications listed in the order documentation.

Configuration review

Dimensions, openings and wall profile reviewed before quotation.

Dispatch terms

EXW Eurodita factory as standard; delivered options per market and order.

How a B2B Order Moves Forward

Each step is confirmed in writing for the specific order. See Reading a Eurodita quotation.

Specification

Specification

Manufacturing scope

Manufacturing scope

Checking and packing

Checking and packing

Dispatch terms

Dispatch terms

Scroll to Top