2 Bedroom Log Cabin 10x6m, 44mm
This 10 x 6 metre residential log cabin delivers substantial living space for families seeking a self-build solution.
Technical Specifications
Add-ons & Customisation
Need this in a different size?
This model is supplied as a 10 x 6 m footprint, 44 mm wall profile. If your customer needs a different layout, send a drawing. Eurodita will confirm whether the qualified bespoke route and factory scope fit the exact project. Partner branding is agreed per order.
- 1 Send a drawing A hand sketch can start the review. Mark known window and door positions, wall thickness and heights; Eurodita confirms any missing technical inputs.
- 2 Confirm the quotation scope If the enquiry fits, pricing and any CAD/3D or technical material are prepared to the agreed scope.
- 3 Review the agreed scope Revisions follow the quotation and project scope until written sign-off.
CAD/3D quotation material is prepared to the qualified project scope. Availability and timing are confirmed during qualification. Partner branding is applied where agreed; required manufacturer, legal and traceability information is retained.
Send a bespoke briefDimensions, wall thickness and opening positions are confirmed per project at quote stage. Bespoke production timing is confirmed in the written quotation and order. See published projects for built examples with dimensions and drawings, or review the rest of the 2 bedroom log cabins range.
About This 2 Bedroom Log Cabin 10x6m, 44mm
Product Overview
This 10 x 6 metre residential log cabin delivers substantial living space for families seeking a self-build solution. The two-bedroom configuration suits accommodation, holiday accommodation, or managed-site accommodation projects. Dealers can offer customers a complete timber kit with professional-grade construction materials and straightforward assembly requirements.
Layout & Configuration
The interior arrangement incorporates two separate bedrooms alongside an open-plan living area. The 60 square metre footprint allows flexible room positioning and furniture placement. Standard height clearance of 2.21 metres at eaves supports comfortable headroom throughout, while the pitched roof design creates additional vertical space in central areas.
Timber & Construction
Slow-grown northern European spruce walls feature 44mm thickness with precision-milled tongue-and-groove joints supporting weather-tight assembly. All doors and windows incorporate double-glazed timber joinery with insulated profiles. The interlocking wall system helps reduce thermal weak points while maintaining assembly stability without mechanical fixings between courses.
Floor & Roof
The floor system uses 28mm tongue-and-groove boards supported by pressure-treated bearers. Roof construction features 19mm tongue-and-groove boarding providing a solid base for weather-protection materials. Storm bracing components support assembly stability, with wind-exposure and loading suitability reviewed through project documentation where required.
Customisation Options
Wall-thickness and insulation upgrades are confirmed at quotation stage for the product family, target use and destination-market review. Additional insulation packages include floor and roof systems for extended-season use. Partition kits enable room subdivision, while veranda extensions increase covered outdoor space. Triple-glazing options deliver project-specific thermal specification for northern European climates.
Manufacturing & Delivery
Production takes place at Eurodita's Kaunas facility, which processes 150,000 cubic metres annually using advanced CNC machinery. Standard delivery across European markets completes within four weeks of order confirmation. The facility handles bespoke modifications including dimensional changes, additional openings, and structural reinforcement requirements.
Private Label Partnership
Private-label programmes enable dealers to market cabins under their own branding. Eurodita provides branded assembly documentation, technical drawings, and 3D visualisation materials. Showroom support programmes include display models and point-of-sale materials. Partner training covers product specifications, assembly guidance, and customer consultation techniques.
What should dealers confirm before quoting 2 Bedroom Log Cabin 10x6m, 44mm?
Eurodita supplies 2 Bedroom Log Cabin 10x6m, 44mm as a private-label B2B residential log cabin with a 10 x 6m footprint and 44mm slow-grown northern European spruce wall specification. Before quoting, dealers should confirm the quote stage package, layout, openings, selected wall or insulation scope, foundation interface, unloading access, EXW release or freight route from Kaunas, private-label documentation, and local-authority planning or site-use review requirements.
Warranty & Support
Structural components carry a ten-year warranty against manufacturing defects and material failures. All timber receives pressure treatment for enhanced durability and pest resistance. Assembly documentation includes detailed drawings, component schedules, and step-by-step instructions. Technical support assists with site preparation requirements and construction queries throughout the build process.
Available exclusively for verified B2B partners
B2B Order Framework
Scope is confirmed in the written quotation and order documentation.
Private-label scope
Branding for packaging and relevant customer-facing documents is agreed per order.
Production planning
Production timing is confirmed in the written quotation and order acknowledgement for the selected model and specification.
Commercial terms
Price, quantity, payment and any volume conditions are quoted for the specific order.
Technical documents
The drawings, specifications and customer-facing documents included in the order are listed in the written quotation.
Configuration review
Dimensions, layout, openings, wall profile and other requested changes are reviewed before they are accepted into the quotation.
Dispatch terms
EXW Kaunas is the standard basis. Any delivered option is agreed for the specific market and order.
How a B2B Order Moves Forward

Specification
Share the model or drawing, destination, quantity and required configuration. Missing technical inputs are confirmed before quotation.

Manufacturing scope
Only the model, options, documentation and branding listed in the accepted order move into production.

Checking and packing
Completed order components are checked and packed against the agreed order scope before factory dispatch.

Dispatch terms
Orders are dispatched from Kaunas under the agreed collection or logistics terms. This does not promise carrier or final-mile delivery performance.