Eurodita is a B2B private-label timber-building manufacturer based in Kaunas, Lithuania, established in 1994. A glulam enquiry is treated as a project-specific manufacturing route. Drawings, engineering inputs, specification, evidence and responsibilities must be reviewed before quotation.

Choose the appropriate glulam procurement route

The route identifies what must be reviewed; it does not establish structural, thermal, fire or local-compliance performance.

RouteUseConfirm before quotation
Selected building conceptA current Eurodita concept is the starting point.Intended use, destination, selected concept, dimensions, changes, complete build-up, quantity and local-review requirements.
Architect-led buildingThe buyer has project drawings and appointed designers.Controlled drawings, design criteria, interfaces, appointed engineering responsibilities, required evidence and logistics route.
Project-specific componentsThe enquiry concerns glulam components rather than a complete building.Member schedule, geometry, connection and tolerance brief, design responsibility, records and acceptance criteria.

Selected building concept

Use
A current Eurodita concept is the starting point.
Confirm before quotation
Intended use, destination, selected concept, dimensions, changes, complete build-up, quantity and local-review requirements.

Architect-led building

Use
The buyer has project drawings and appointed designers.
Confirm before quotation
Controlled drawings, design criteria, interfaces, appointed engineering responsibilities, required evidence and logistics route.

Project-specific components

Use
The enquiry concerns glulam components rather than a complete building.
Confirm before quotation
Member schedule, geometry, connection and tolerance brief, design responsibility, records and acceptance criteria.

Define engineering and documentation responsibility

The buyer and its appointed engineers or other professionals define the design criteria and confirm the destination-market review route. Eurodita confirms the manufacturable scope, production information and documents included or available for the quoted order.

Controlled inputs

Submit one current drawing and specification revision, including interfaces and acceptance criteria.

Evidence scope

Identify the exact technical or material evidence needed; availability is confirmed for the quoted project.

Commercial route

Price, quantity, specification, payment terms and production scope are confirmed in the written quotation and order. This page does not publish a fixed price, order volume or production slot.

Timing and logistics

Factory-release timing is confirmed only in the written quotation and order after the product, specification, quantity, documentation scope and production plan are reviewed. Freight and final delivery timing are confirmed separately for the agreed route.

Controlled 220 mm evidence pack: revision and buyer inputs

Eurodita uses order-specific production drawings to connect a quoted specification to manufacturing information and the supplied component pack. The public evidence below is a sanitised derivative of an actual Eurodita-owned order pack. It is technical qualification evidence, not a construction issue for another building.

Document ID
EDT-GLU-TEB-220-001
Revision
A
Issue date
18 August 2026
Status
Public technical evidence brief
Scope
220 mm order-specific glulam documentation evidence
Source class
Sanitised Eurodita-owned production drawing excerpts
Review trigger
Source/control change or 18 November 2026
Public owner
/glulam-b2b-supply/

Public drawing index

PlateEvidence shownSupports review ofDoes not prove
01Outside-corner seal zones and first-row interfaceWall type, detail coordination and foundation-line information needFoundation design, moisture performance, fixing or tolerance
0238 x 98 mm opening components in one 220 mm exampleWall/opening component matching and revision controlTransferability to another opening or project
03Selected rain, corner and levelling board sectionsDocumented finishing interfaces and section identificationUniversal finish, treatment or quantity
04Axonometric wall and beam progressionOrientation and relation between assembly views and detailed sheetsSite method, temporary works or installation sign-off
05Floor and roof element mappingLayout coordination and required interface questionsLoads, spans, bearing, fixings or structural performance

Send one controlled technical brief

  • Intended use and building location.
  • Current drawing and specification revision.
  • Wall/build-up and required interfaces.
  • Openings, services and foundation information.
  • Design and local-approval responsibility split.
  • Required technical or material evidence.
  • Quantity, target timing and logistics route.
  • Named technical and commercial contacts.

Hold before quotation or release when

  • Revisions conflict or approval status is unclear.
  • Site, foundation, openings or services lack an owner.
  • A performance or compliance claim lacks applicable evidence.
  • The physical pack cannot be matched to the controlled record.
  • A discrepancy is being solved through undocumented site improvisation.

Public-use boundary: customer identity, project code, constructor identity, services layout, full floor plan, quantities, bill of materials, cut list and private production references are excluded. This evidence does not establish structural, thermal, fire, acoustic or regulatory performance and does not replace the current approved order-specific drawing set.

What an order-specific 220 mm drawing pack controls

The drawings below are sanitised excerpts from an actual Eurodita production and assembly pack. They are not marketing diagrams. The source set contains the project arrangement, wall and opening details, assembly views, floor and roof layouts, numbered components and a production schedule.

In this order, 220 mm identifies the wall type and 220 x 260 mm appears as a component-profile reference in the production schedule. Neither value is a U-value, fire rating, structural capacity or certification statement. The dimensions shown below belong to this project example only.

Outside-corner geometry and the first row

The corner detail identifies controlled spaces for non-expanding sealing foam and isolation or sealing tape. A separate first-row drawing connects the wall profile to the rain board and foundation line. In this pack, the drawing calls for two rows of isolation tape between 220 mm logs and one row for the 135 mm wall type used elsewhere in the same order.

Actual Eurodita Drawing Excerpts Showing The 220 Mm Outside-Corner Seal Zones And First-Row Interface
Order-specific corner and first-row details. Values shown apply only to the cited production pack.

Foundation geometry, moisture separation, fixing and tolerance requirements remain project inputs.

Door and window opening pieces

The 220 mm wall example uses impregnated 38 x 98 mm opening components. The same order also records 38 x 68 mm pieces for a 135 mm wall type, which shows why a component must be matched to both its wall type and drawing reference.

Actual Eurodita Drawing Excerpts Showing 38 X 98 Mm Opening Pieces In The 220 Mm Wall Set
Opening-edge arrangement and component mapping from the actual order drawing set.

Exterior finishing components

Selected examples include a 28 x 60 mm rain board, 40 x 140 mm and 40 x 180 mm outside-corner boards, and 19 x 80 mm or 19 x 100 mm levelling boards.

Actual Eurodita Drawing Excerpts Showing Rain-Board, Corner-Board And Levelling-Board Sections
Selected finishing sections from one order-specific production schedule.

Assembly progression

The axonometric sheets show the building at successive wall and beam stages. They allow the site team to relate wall courses and openings to the developing beam structure before moving to the more detailed dimensioned sheets.

Two Actual Eurodita Axonometric Drawing Excerpts Showing Order-Specific Wall And Beam Stages
The 3D views provide orientation. The current dimensioned drawings remain the controlling source.

Floor and roof element maps

In this example, the floor drawing identifies 19 x 100 (130) mm boards over exposed beams, while the roof drawing maps 45 x 58 mm doubling slats in the order-specific layout.

Actual Eurodita Floor And Roof Drawing Excerpts With Dimensioned Element Mapping
Order-specific floor and roof element mapping. Span, bearing, loads and fixings require separate project checks.

Information and responsibility boundary

InformationWhat the drawing pack providesWhat remains project-specific
Wall and opening componentsGeometry, section, cut length and drawing relationshipFinal order applicability and approved revision
Corner and finishing piecesDimensioned component detailsFinish, treatment, quantity and site sequence
Floor and roof layoutsElement mapping and order-specific dimensionsStructural checks, loads, bearing and fixings
Assembly viewsOrientation and sequencing contextSite method, temporary works and local supervision
Technical releaseControlled drawing and schedule setAcceptance by the responsible project parties

The complete project pack remains a controlled order deliverable. Review Eurodita's construction guides, dealer resources and shipping and delivery policy for the wider information and responsibility route.

Frequently asked questions

Are these drawings real Eurodita production drawings?

Yes. The images are sanitised excerpts from a Eurodita-owned 56-page production and assembly pack prepared for one customer order. Client identity, project codes, services, quantities and private production references have been removed.

Can these dimensions be used for another building?

No. They demonstrate how one order was documented. Another building can require different profiles, sections, lengths, interfaces and engineering checks.

Does the drawing prove thermal, fire or regulatory performance?

No. The pack does not by itself establish a U-value, fire classification, Eurocode compliance, CE or UKCA status, permit approval or building-regulation compliance.

What should an architect, dealer or installer request for a live order?

They should identify the order, building location, current revision, responsible technical contacts, site and foundation information, openings, services and any unresolved interfaces. Eurodita can then define the applicable order-specific documentation route.

Use boundary: These are project-specific drawing excerpts shown for technical context. They are not a structural, thermal, fire-safety or regulatory design and must not be used as a construction instruction for another project. Manufacture and assembly follow the current approved order-specific drawing set and the checks of the responsible project designer.

No blanket performance or certification claim

The buyer and its appointed local professionals or authorities must confirm site classification, planning, building control, applicable standards, foundations, services, installation, access and safety requirements for the destination and intended use. Eurodita confirms its quoted factory and documentation scope.

Customer-facing branding, labels, documents and packing are agreed per order. Required manufacturer, legal, traceability, technical and operational information is retained where necessary.

Any warranty applies only as stated in the written quotation, order and warranty terms for the eligible product or component. It is not an automatic whole-building, performance or local-compliance guarantee.

Frequently Asked Questions

What information is required for a glulam quotation?

Provide intended use, destination, controlled drawings, engineering criteria, complete build-up, interfaces, required documents, quantity, target timing and logistics route.

Does a glulam product name establish structural or thermal performance?

No. Performance depends on the confirmed design, specification, evidence, installation and local review. Those items are project specific.

Who owns the engineering and local approval route?

The buyer and appointed project professionals own the design criteria and local approval route. Eurodita confirms only its quoted manufacturing and documentation scope.

How are timing and quantity confirmed?

They are confirmed in the written quotation and order after technical review and production planning. Freight timing is confirmed separately.

Can the order use the buyer's brand?

Customer-facing branding, labels, documents and packing are agreed per order. Required manufacturer, legal, traceability, technical and operational information is retained where necessary.

Submit a controlled glulam brief

Send the current drawings, engineering responsibility split, evidence requirements, quantity and logistics route for qualification.

Scroll to Top