Eurodita Twin Skin three bed log cabin 9x8m
The Twin Skin Three Bed Log Cabin delivers 72 m² of insulated usable internal floor area within a 9 x 8 m footprint .
Technical Specifications
Add-ons & Customisation
Need this in a different size?
This model is supplied as a 9 x 8 m footprint. If your customer needs a different layout, send a drawing. Eurodita will confirm whether the qualified bespoke route and factory scope fit the exact project. Partner branding is agreed per order.
- 1 Send a drawing A hand sketch can start the review. Mark known window and door positions, wall thickness and heights; Eurodita confirms any missing technical inputs.
- 2 Confirm the quotation scope If the enquiry fits, pricing and any CAD/3D or technical material are prepared to the agreed scope.
- 3 Review the agreed scope Revisions follow the quotation and project scope until written sign-off.
CAD/3D quotation material is prepared to the qualified project scope. Availability and timing are confirmed during qualification. Partner branding is applied where agreed; required manufacturer, legal and traceability information is retained.
Send a bespoke briefDimensions, wall thickness and opening positions are confirmed per project at quote stage. Bespoke production timing is confirmed at quotation stage. See published projects for built examples with dimensions and drawings, or review the rest of the 3 bedroom log cabins range.
About This Eurodita Twin Skin three bed log cabin 9x8m
Product Overview
The Twin Skin Three Bed Log Cabin delivers 72 m² of insulated usable internal floor area within a 9 x 8 m footprint. The double-wall construction supports higher-specification project briefs where final use, insulation package and local-authority review route are confirmed per project. Manufactured by UAB Eurodita in Kaunas, Lithuania. Explore configurations in the log cabin catalogue.
Thermal Package & Project Review
The twin-skin system uses dual timber wall layers with an insulated cavity. Final thermal specification depends on the confirmed wall build-up, insulation, glazing, roof, floor, ventilation, installation quality and local authority review route. The cavity is the space insulation occupies. Eurodita supplies the timber structure prepared for insulation and does not normally supply the insulation materials, so a cavity dimension does not by itself specify insulation. These dimensions do not by themselves establish thermal, fire, structural or project suitability.
Timber & Construction (Double-Wall System)
All timber components from Northern European timber, kiln-dried in Nardi kilns (Italy) to a 12-14% production moisture target. Wall profiles machined on Hundegger CNC centres (Germany) deliver specified acoustic insulation scope between rooms.
Layout & Configuration
The 9 x 8 m floor plan accommodates three bedrooms, an open-plan living and kitchen area, and a bathroom. Proportions allow practical hallway distribution separating bedroom and living zones.
Customisation Options
Fully configurable: room layout, window and door positions, glazing, roof style, insulation depth, and exterior finish. Standard catalogue production lead time is confirmed per order at quote stage.
Manufacturing & Delivery
Produced at UAB Eurodita in Kaunas, Lithuania. Production timing is confirmed in the written quotation and order. Delivered as a comprehensive flat-pack kit. Production timing is confirmed per order at quote stage.
Private Label Partnership
Private-label branding, packaging and customer-facing documentation are agreed perorder. The customer-facing branding and documentation scope is confirmed for each private-label order.
What should dealers confirm before quoting Eurodita Twin Skin three bed log cabin 9x8m?
Eurodita supplies Eurodita Twin Skin three bed log cabin 9x8m as a private-label B2B Twin Skin log cabin with a 9 x 8m footprint and Twin Skin wall build-up confirmed in the quotation package. Before quoting, dealers should confirm the quote stage package, layout, openings, selected wall or insulation scope, foundation interface, unloading access, EXW release or freight route from Kaunas, private-label documentation, and local-authority planning or site-use review requirements.
Product, order and after-sales conditions are confirmed in writing for each project in the quotation, order confirmation and applicable product documentation. Please contact Eurodita for the documentation relevant to your confirmed order.Technical data sheet
Specification recorded for Eurodita Twin Skin three bed log cabin 9x8m. Dimensions are the building's external dimensions. A row appears only where a figure is recorded for this model.
Building External dimensions 9 x 8 m Eaves height 220 cm Ridge height 312 cm Storeys 1 Base External footprint 9 x 8 m. Base type and size are confirmed for the specific model and site. Structure Wall build-up 44-100-44 mm: 44 mm outer skin, 100 mm cavity, 44 mm inner skin. 188 mm total wall thickness. Other wall options The other approved twin-skin build-ups and solid wall profiles can be specified to suit the project and budget. Construction Interlocking tongue and groove joints Timber Northern European timber Storm brace and anchor set Included Floor Floor bearers Impregnated as standard Floor boards 28 mm Roof Roof boards 19 mm tongue and groove boards Doors and windows Doors Double-Glazed Timber Joinery, Insulated Profile Windows Double-Glazed Timber Joinery, Insulated Profile Scope of these figures Insulation The 100 mm cavity is the space insulation occupies. Eurodita supplies the structure prepared for insulation, not the insulation material, so the cavity dimension is not an insulation specification. Availability Build-up availability and suitability for a given project and destination are confirmed per order. Performance These dimensions establish no thermal, fire, structural or certification performance.
Technical data sheet
Specification recorded for Eurodita Twin Skin three bed log cabin 9x8m. Dimensions are the building's external dimensions. A row appears only where a figure is recorded for this model.
| Building | |
|---|---|
| External dimensions | 9 x 8 m |
| Eaves height | 220 cm |
| Ridge height | 312 cm |
| Storeys | 1 |
| Base | External footprint 9 x 8 m. Base type and size are confirmed for the specific model and site. |
| Structure | |
| Wall build-up | 44-100-44 mm: 44 mm outer skin, 100 mm cavity, 44 mm inner skin. 188 mm total wall thickness. |
| Other wall options | The other approved twin-skin build-ups and solid wall profiles can be specified to suit the project and budget. |
| Construction | Interlocking tongue and groove joints |
| Timber | Northern European timber |
| Storm brace and anchor set | Included |
| Floor | |
| Floor bearers | Impregnated as standard |
| Floor boards | 28 mm |
| Roof | |
| Roof boards | 19 mm tongue and groove boards |
| Doors and windows | |
| Doors | Double-Glazed Timber Joinery, Insulated Profile |
| Windows | Double-Glazed Timber Joinery, Insulated Profile |
| Scope of these figures | |
| Insulation | The 100 mm cavity is the space insulation occupies. Eurodita supplies the structure prepared for insulation, not the insulation material, so the cavity dimension is not an insulation specification. |
| Availability | Build-up availability and suitability for a given project and destination are confirmed per order. |
| Performance | These dimensions establish no thermal, fire, structural or certification performance. |
B2B Order Framework
Scope is confirmed in the written quotation and order documentation.
Private-label scope
Branding for packaging and relevant customer-facing documents is agreed per order.
Production planning
Production timing is confirmed in the written quotation and order acknowledgement for the selected model and specification.
Commercial terms
Price, quantity, payment and any volume conditions are quoted for the specific order.
Technical documents
The drawings, specifications and customer-facing documents included in the order are listed in the order documentation.
Configuration review
Dimensions, layout, openings, wall profile and other requested changes are reviewed before they are accepted into the quotation.
Dispatch terms
EXW Kaunas is the standard basis. Any delivered option is agreed for the specific market and order.
How a B2B Order Moves Forward

Specification
Share the model or drawing, destination, quantity and required configuration. Missing technical inputs are confirmed before quotation.

Manufacturing scope
Only the model, options, documentation and branding listed in the accepted order move into production.

Checking and packing
Completed order components are checked and packed against the agreed order scope before factory dispatch.

Dispatch terms
Orders are dispatched from Kaunas under the agreed collection or logistics terms. This does not promise carrier or final-mile delivery performance.