Technical Specifications

Wall Thickness:
88mm
Construction:
Strong interlocking tongue & groove joints
External dimensions:
17x7m
Eaves Height (cm):
210
Ridge Height (cm):
297
Material:
Engineered Glulam Timber
Doors:
Double-Glazed Timber Joinery, Insulated Profile
Windows:
Double-Glazed Timber Joinery, Insulated Profile
Floor Boards:
28mm
Floor Bearers:
13.5x13.5 cm Glulam
Roof:
Tongue & groove boards: 19mm
Storm brace & anchor set:
Included

Add-ons & Customisation

✅ Logo branding on drawings and packaging
✅ Wall thickness upgrade
✅ Roof & floor insulation
✅ Optional wall liner insulation
✅ Roof board 28 mm & rafter upgrade
✅ Project-specific glazing options
✅ Extra windows / repositioning / skylight
✅ Internal partitions + door kits
✅ Veranda/canopy/storage annex
✅ Production schedule review
✅ Dealer presentation support

Need this in a different size?

This model is supplied as a 17 x 7 m footprint. If your customer needs a different layout, send a drawing. Eurodita will confirm whether the qualified bespoke route and factory scope fit the exact project. Partner branding is agreed per order.

  1. 1 Send a drawing A hand sketch can start the review. Mark known window and door positions, wall thickness and heights; Eurodita confirms any missing technical inputs.
  2. 2 Confirm the quotation scope If the enquiry fits, pricing and any CAD/3D or technical material are prepared to the agreed scope.
  3. 3 Review the agreed scope Revisions follow the quotation and project scope until written sign-off.

CAD/3D quotation material is prepared to the qualified project scope. Availability and timing are confirmed during qualification. Partner branding is applied where agreed; required manufacturer, legal and traceability information is retained.

Send a bespoke brief

Dimensions, wall thickness and opening positions are confirmed per project at quote stage. Bespoke production timing is confirmed in the written quotation and order. See published projects for built examples with dimensions and drawings, or review the rest of the mobile log homes range.

About This Mobile Log Home 2 Bed 17x7m

Product Overview

This two-bedroom mobile log home delivers 119m² of living space within a 17x7m footprint configured around UK Caravan Sites Act 1968 (as amended by SI 2006/2374) dimensional criteria for dealer and local-authority review. The spacious two-bedroom configuration serves couples, small families and managed-site operators planning multi-room accommodation with generous communal areas. The full-height 297cm ridge construction provides generous interior volume while keeping transport planning subject to the confirmed route and project documentation.

Layout and Configuration

Within the 17x7m footprint, two bedrooms of comfortable proportion adjoin a shared bathroom and an expansive open-plan living and kitchen area. The generous dimensions permit en-suite potential for the principal bedroom and allow flexible furniture configurations throughout the communal spaces. The standard 220cm eaves height ensures comfortable headroom throughout, with the apex roof profile creating additional storage opportunities above partition walls.

Timber and Construction

Slow-grown northern European spruce forms 88mm thick exterior walls using precision-machined tongue-and-groove profiles for assembly integrity and weather-exposure review. Double-glazed timber joinery incorporates insulated door and window frames throughout the structure. Internal partition walls integrate with the exterior envelope to create a coordinated wall framework. Load distribution across the two-bedroom layout requires engineered connection details at wall intersections, supporting dimensional stability under sustained project loading.

Floor and Roof

Pressure-treated 13.5×13.5cm glulam floor bearers support 28mm tongue-and-groove floor boarding specified for project-use requirements across the full 119m² floor plate. Roof construction utilises 19mm tongue-and-groove boards providing a solid substrate for insulation and selected roof covering systems. Bearer spacing accounts for the wider span dimensions typical of two-bedroom configurations, with additional bearers positioned beneath partition wall lines. Roof bracing systems are engineered for the intermediate span, providing resistance to lateral and uplift forces across the extended floor plate.

Customisation Options

Glulam wall-profile and insulation options are confirmed at quote stage according to the project brief, destination climate and local-authority review route. Additional insulation packages, triple-glazing options, and alternative door and window configurations are specified for the destination climate and local project review route. Two-bedroom models offer bedroom partition configuration alternatives, en-suite bathroom options for the principal bedroom, and flexible kitchen layout arrangements. Internal door and corridor positioning can be adjusted to suit specific site orientation and operator requirements.

Manufacturing and Delivery

Production at the Eurodita facility in Kaunas, Lithuania uses Hundegger CNC cutting systems and Nardi kiln-drying technology for northern European spruce components. Production and logistics timing is confirmed per order according to specification, order volume, factory planning, transport route and site-access needs. Transport requirements for the two-bedroom package are confirmed per order against haulage dimensions and route planning. Delivery scheduling coordinates with site preparation timelines to minimise on-site storage requirements. Assembly typically requires a three-to-four person crew over five to seven working days.

Private Label Partnership

Private-label manufacturing enables dealers to supply this mobile home under their own brand identity with no visible Eurodita branding on the delivered product. Partner support includes customised assembly documentation, branded customer communications, and 3D visualisation tools for showroom and catalogue presentation. Flexible order volumes accommodate both individual project requirements and ongoing supply agreements for holiday-park, managed-site and accommodation operators.

Warranty and Support

Product, order and after-sales conditions are confirmed in writing for each project in the quotation, order confirmation and applicable product documentation. Please contact Eurodita for the documentation relevant to your confirmed order. Technical documentation includes detailed assembly drawings, hardware schedules, foundation guidance, and ongoing maintenance recommendations. Dedicated partner managers provide specification support, project quotation assistance, and after-sales technical consultation. Two-bedroom mobile homes provide a mid-range option for regional markets, balancing manufacturing complexity with project demand for multi-room accommodation layouts.

Request Trade Pricing →

Available exclusively for verified B2B partners

What should dealers verify before quoting Mobile Log Home 2 Bed 17x7m?

Eurodita manufactures Mobile Log Home 2 Bed 17x7m as an 88mm engineered glulam mobile log home for private-label B2B partners. Before quoting, dealers should confirm the project route against Eurodita's Mobile Log Homes B2B range, the BS 3632 project-review route where relevant, site-licence or local-authority checks, layout changes, services, documentation scope and EXW Kaunas logistics. Final specification suitability, siting route and approval remain with the dealer, site operator, local authority or appointed assessor.

UK siting note

This model is 7.0 m wide, above the 6.8 m maximum width in the UK caravan definition (Caravan Sites Act 1968 s.13, as amended by SI 2006/2374, which sets 20.0 m length, 6.8 m width and 3.05 m internal height). It remains available for markets where that definition does not apply. For a UK project the siting and approval route is confirmed per project with the dealer, client and local authority before quotation. Narrower layouts within the definition are available on request.

B2B Order Framework

Scope is confirmed in the written quotation and order documentation.

Private-label scope

Branding for packaging and relevant customer-facing documents is agreed per order.

Production planning

Production timing is confirmed in the written quotation and order acknowledgement for the selected model and specification.

Commercial terms

Price, quantity, payment and any volume conditions are quoted for the specific order.

Technical documents

The drawings, specifications and customer-facing documents included in the order are listed in the written quotation.

Configuration review

Dimensions, layout, openings, wall profile and other requested changes are reviewed before they are accepted into the quotation.

Dispatch terms

EXW Kaunas is the standard basis. Any delivered option is agreed for the specific market and order.

How a B2B Order Moves Forward

Specification

Specification

Share the model or drawing, destination, quantity and required configuration. Missing technical inputs are confirmed before quotation.

Manufacturing scope

Manufacturing scope

Only the model, options, documentation and branding listed in the accepted order move into production.

Checking and packing

Checking and packing

Completed order components are checked and packed against the agreed order scope before factory dispatch.

Dispatch terms

Dispatch terms

Orders are dispatched from Kaunas under the agreed collection or logistics terms. This does not promise carrier or final-mile delivery performance.

Scroll to Top