Eurodita Twin Skin four bed log cabin 13x8m
Technical Specifications
Add-ons & Customisation
Need this in a different size?
This model is supplied as a 13 x 8 m footprint. If your customer needs a different layout, send a drawing. Eurodita will confirm whether the qualified bespoke route and factory scope fit the exact project. Partner branding is agreed per order.
- 1 Send a drawing A hand sketch can start the review. Mark known window and door positions, wall thickness and heights; Eurodita confirms any missing technical inputs.
- 2 Confirm the quotation scope If the enquiry fits, pricing and any CAD/3D or technical material are prepared to the agreed scope.
- 3 Review the agreed scope Revisions follow the quotation and project scope until written sign-off.
CAD/3D quotation material is prepared to the qualified project scope. Availability and timing are confirmed during qualification. Partner branding is applied where agreed; required manufacturer, legal and traceability information is retained.
Send a bespoke briefDimensions, wall thickness and opening positions are confirmed per project at quote stage. Bespoke production timing is confirmed in the written quotation and order. See published projects for built examples with dimensions and drawings, or review the rest of the 4 bedroom log cabins range.
About This Eurodita Twin Skin four bed log cabin 13x8m
Product Overview
Developers and contractors requiring substantial accommodation capacity will find the Twin Skin four-bed log cabin delivers comprehensive accommodation within 13 x 8 metres. This insulated double-wall structure provides four distinct bedrooms alongside generous communal areas, making it suitable for family housing projects, holiday developments, or extended project applications requiring project-specific use standards.
Layout & Configuration
Four separate bedrooms are configured alongside kitchen, bathroom, and living areas within the 104 square metre footprint. The 220cm eaves height supports comfortable headroom throughout ground floor areas, while the pitched roof design creates additional upper-level potential for storage or recreational use depending on planning requirements.
Timber & Construction
Slow-grown northern European spruce forms the 44-100-44mm twin-skin wall system, incorporating an insulation cavity between structural layers. Strong interlocking tongue-and-groove joints ensure weather-tight assembly, while double-glazed timber joinery with insulated profiles provides thermal specification reviewed for extended-season use across European climate zones.
Floor & Roof
The structural floor incorporates 28mm boards over pressure-treated bearers, providing stable foundations for project loading. Roof construction features 19mm tongue-and-groove boards with integrated storm bracing, supporting assembly stability under wind and snow loads typical of Northern European installations.
Customisation Options
Wall thickness upgrades accommodate enhanced insulation requirements, while glazing specifications can be adjusted for specific thermal specification targets. Internal partition configurations allow room layout modifications, and veranda extensions provide covered outdoor areas. Self-build contractors benefit from modular assembly systems designed for site construction efficiency.
Manufacturing & Delivery
Eurodita processes 150,000 m³ of timber annually. Any requested production schedule is confirmed only after the specification and production plan are reviewed for the order.
Private Label Partnership
Trade partners access private-label manufacturing capability with branded documentation and technical specifications. 3D visualisation services support customer presentations, while showroom display programmes provide physical demonstrations. This partnership structure enables dealers to offer comprehensive residential timber solutions under their own commercial identity.
What should dealers confirm before quoting Eurodita Twin Skin four bed log cabin 13x8m?
Eurodita supplies Eurodita Twin Skin four bed log cabin 13x8m as a private-label B2B Twin Skin log cabin with a 13 x 8m footprint and a source-listed Twin Skin build-up of 44-100-44mm. Before quoting, dealers should confirm the quote stage package, layout, openings, selected wall or insulation scope, foundation interface, unloading access, EXW release or freight route from Kaunas, private-label documentation, and local-authority planning or site-use review requirements.
Product, order and after-sales conditions are confirmed in writing for each project in the quotation, order confirmation and applicable product documentation. Please contact Eurodita for the documentation relevant to your confirmed order.
B2B Order Framework
Scope is confirmed in the written quotation and order documentation.
Private-label scope
Branding for packaging and relevant customer-facing documents is agreed per order.
Production planning
Production timing is confirmed in the written quotation and order acknowledgement for the selected model and specification.
Commercial terms
Price, quantity, payment and any volume conditions are quoted for the specific order.
Technical documents
The drawings, specifications and customer-facing documents included in the order are listed in the written quotation.
Configuration review
Dimensions, layout, openings, wall profile and other requested changes are reviewed before they are accepted into the quotation.
Dispatch terms
EXW Kaunas is the standard basis. Any delivered option is agreed for the specific market and order.
How a B2B Order Moves Forward

Specification
Share the model or drawing, destination, quantity and required configuration. Missing technical inputs are confirmed before quotation.

Manufacturing scope
Only the model, options, documentation and branding listed in the accepted order move into production.

Checking and packing
Completed order components are checked and packed against the agreed order scope before factory dispatch.

Dispatch terms
Orders are dispatched from Kaunas under the agreed collection or logistics terms. This does not promise carrier or final-mile delivery performance.