Technical data sheet

Specification recorded for Eurodita Twin Skin four bed log cabin 13x8m. Dimensions are the building's external dimensions. A row appears only where a figure is recorded for this model.

Building
External dimensions13 x 8 m
External footprint area104 m²
Eaves height220 cm
Ridge height312 cm
BaseExternal footprint 13 x 8 m. Base type and size are confirmed for the specific model and site.
Structure
Wall build-up44-100-44 mm: 44 mm outer skin, 100 mm cavity, 44 mm inner skin. 188 mm total wall thickness.
Other wall optionsThe other approved twin-skin build-ups and solid wall profiles can be specified to suit the project and budget.
ConstructionInterlocking tongue and groove joints
TimberNorthern European timber
Storm brace and anchor setIncluded
Floor
Floor bearersImpregnated as standard
Floor boards28 mm
Roof
Roof boards19 mm tongue and groove boards
Doors and windows
DoorsDouble-Glazed Timber Joinery, Insulated Profile
WindowsDouble-Glazed Timber Joinery, Insulated Profile
Scope of these figures
InsulationThe 100 mm cavity is the space insulation occupies. Eurodita supplies the structure prepared for insulation, not the insulation material, so the cavity dimension is not an insulation specification.
AvailabilityBuild-up availability and suitability for a given project and destination are confirmed per order.
PerformanceThese dimensions establish no thermal, fire, structural or certification performance.

Download technical data sheet (PDF) Wall profile reference

Add-ons & Customisation

Options for this model (branding, wall thickness, openings, insulation preparation, partitions, veranda) are listed on What is in a Eurodita kit and confirmed per order.

Need this in a different size?

This model is supplied as a 13 x 8 m footprint. If your customer needs a different layout, send a drawing. Eurodita will confirm whether the qualified bespoke route and factory scope fit the exact project. Partner branding is agreed per order.

  1. 1 Send a drawing A hand sketch can start the review. Mark known window and door positions, wall thickness and heights; Eurodita confirms any missing technical inputs.
  2. 2 Confirm the quotation scope If the enquiry fits, pricing and any CAD/3D or technical material are prepared to the agreed scope.
  3. 3 Review the agreed scope Revisions follow the quotation and project scope until written sign-off.

CAD/3D quotation material is prepared to the qualified project scope. Availability and timing are confirmed during qualification. Partner branding is applied where agreed; required manufacturer, legal and traceability information is retained.

Send a bespoke brief

Dimensions, wall thickness and opening positions are confirmed per project at quote stage. Bespoke production timing is confirmed at quotation stage. See published projects for built examples with dimensions and drawings, or review the rest of the 4 bedroom log cabins range.

About This Eurodita Twin Skin four bed log cabin 13x8m

Product Overview

Developers and contractors requiring substantial accommodation capacity will find the Twin Skin four-bed log cabin delivers comprehensive accommodation within 13 x 8 metres. This insulated double-wall structure provides four distinct bedrooms alongside generous communal areas, making it suitable for family housing projects, holiday developments, or extended project applications requiring project-specific use standards.

Layout & Configuration

Four separate bedrooms are configured alongside kitchen, bathroom, and living areas within the 104 square metre footprint. The 220cm eaves height supports comfortable headroom throughout ground floor areas, while the pitched roof design creates additional upper-level potential for storage or recreational use depending on planning requirements.

Timber & Construction

Northern European timber forms the 44-100-44mm twin-skin wall system, incorporating an insulation cavity between structural layers. The cavity is the space insulation occupies. Eurodita supplies the timber structure prepared for insulation and does not normally supply the insulation materials, so a cavity dimension does not by itself specify insulation. These dimensions do not by themselves establish thermal, fire, structural or project suitability. Strong interlocking tongue-and-groove joints ensure weather-tight assembly, while double-glazed timber joinery with insulated profiles provides thermal specification reviewed for extended-season use across European climate zones.

Floor & Roof

The structural floor incorporates 28mm boards over pressure-treated bearers, providing stable foundations for project loading. Roof construction features 19mm tongue-and-groove boards with integrated storm bracing, supporting assembly stability under wind and snow loads typical of Northern European installations.

Customisation Options

Wall thickness upgrades accommodate enhanced insulation requirements, while glazing specifications can be adjusted for specific thermal specification targets. Internal partition configurations allow room layout modifications, and veranda extensions provide covered outdoor areas. Self-build contractors benefit from modular assembly systems designed for site construction efficiency.

Manufacturing & Delivery

Eurodita processes 150,000 m³ of timber annually. Any requested production schedule is confirmed only after the specification and production plan are reviewed for the order.

Private Label Partnership

Trade partners access private-label manufacturing capability with branded documentation and technical specifications. 3D visualisation services support customer presentations, while showroom display programmes provide physical demonstrations. This partnership structure enables dealers to offer comprehensive residential timber solutions under their own commercial identity.

What should dealers confirm before quoting Eurodita Twin Skin four bed log cabin 13x8m?

Eurodita supplies Eurodita Twin Skin four bed log cabin 13x8m as a private-label B2B Twin Skin log cabin with a 13 x 8m footprint and a source-listed Twin Skin build-up of 44-100-44mm. Before quoting, dealers should confirm the quote stage package, layout, openings, selected wall or insulation scope, foundation interface, unloading access, EXW release or freight route from Kaunas, private-label documentation, and local-authority planning or site-use review requirements.

Product, order and after-sales conditions are confirmed in writing for each project in the quotation, order confirmation and applicable product documentation. Please contact Eurodita for the documentation relevant to your confirmed order.

B2B Order Framework

Scope is confirmed in the written quotation. Details: Reading a Eurodita quotation.

Private-label scope

Branding on packaging and documents, agreed per order.

Production planning

Production scope confirmed in the written quotation.

Commercial terms

Price, quantity and payment quoted per order.

Technical documents

Drawings and specifications listed in the order documentation.

Configuration review

Dimensions, openings and wall profile reviewed before quotation.

Dispatch terms

EXW Kaunas as standard; delivered options per market and order.

How a B2B Order Moves Forward

Each step is confirmed in writing for the specific order. See Reading a Eurodita quotation.

Specification

Specification

Manufacturing scope

Manufacturing scope

Checking and packing

Checking and packing

Dispatch terms

Dispatch terms