Eurodita Twin Skin four bed log cabin 16x9m
This 16x9m four-bedroom twin skin log cabin is a large specification package for dealers, contractors and project teams reviewing multi-room timber-building briefs.
Technical Specifications
Add-ons & Customisation
Need this in a different size?
This model is supplied as a 16 x 9 m footprint. If your customer needs a different layout, send a drawing. Eurodita will confirm whether the qualified bespoke route and factory scope fit the exact project. Partner branding is agreed per order.
- 1 Send a drawing A hand sketch can start the review. Mark known window and door positions, wall thickness and heights; Eurodita confirms any missing technical inputs.
- 2 Confirm the quotation scope If the enquiry fits, pricing and any CAD/3D or technical material are prepared to the agreed scope.
- 3 Review the agreed scope Revisions follow the quotation and project scope until written sign-off.
CAD/3D quotation material is prepared to the qualified project scope. Availability and timing are confirmed during qualification. Partner branding is applied where agreed; required manufacturer, legal and traceability information is retained.
Send a bespoke briefDimensions, wall thickness and opening positions are confirmed per project at quote stage. Bespoke production timing is confirmed at quotation stage. See published projects for built examples with dimensions and drawings, or review the rest of the 4 bedroom log cabins range.
About This Eurodita Twin Skin four bed log cabin 16x9m
Product Overview
This 16x9m four-bedroom twin skin log cabin is a large specification package for dealers, contractors and project teams reviewing multi-room timber-building briefs. The twin skin construction and integrated insulation layer are supplied as technical specification inputs, with final use, insulation, heating, ventilation and local requirements reviewed per project.
Layout & Configuration
The 144 square metre floor area accommodates four bedrooms with flexible interior partitioning options. The 2.1m eaves height creates comfortable living spaces, while the pitched roof design reaches 3.12m at ridge. Multiple room configurations allow developers to adapt layouts for specific market requirements or customer specifications.
Timber & Construction
Northern European timber forms the 44-100-44mm twin skin wall system with precision interlocking tongue and groove joints. The insulation cavity and double-glazed timber joinery are documented as part of the project specification for dealer, project team and local authority review where relevant. The cavity is the space insulation occupies. Eurodita supplies the timber structure prepared for insulation and does not normally supply the insulation materials, so a cavity dimension does not by itself specify insulation. These dimensions do not by themselves establish thermal, fire, structural or project suitability.
Floor & Roof
Engineered 28mm floor boards install over pressure-treated bearer systems for long-term assembly stability. The roof incorporates 19mm tongue and groove boarding with integrated storm bracing. This specification supports project documentation review while maintaining the authentic timber aesthetic that distinguishes log cabin construction from conventional housing.
Customisation Options
Wall thickness upgrades accommodate specific thermal requirements, while additional insulation packages meet enhanced energy standards. Glazing specifications adapt to local climate conditions and planning requirements. Interior partition kits enable custom room layouts, and veranda extensions create covered outdoor spaces to maximize the residential appeal.
Manufacturing & Delivery
Eurodita processes 150,000 m³ of timber annually. Freight route and final delivery timing are agreed per order in the written quotation. Eurodita's standard terms are EXW from Kaunas. The facility accommodates bespoke modifications, enabling dealers to specify dimensional changes or unique features for project-specific timber-building briefs.
Private Label Partnership
Private-label manufacturing enables retailers to market under their own branding with customized documentation and promotional materials. Professional 3D visualization services support sales presentations and planning applications. Display models for a partner's showroom can be quoted per order.
What should dealers confirm before quoting Eurodita Twin Skin four bed log cabin 16x9m?
Eurodita supplies Eurodita Twin Skin four bed log cabin 16x9m as a private-label B2B Twin Skin log cabin with a 16 x 9m footprint and a source-listed Twin Skin build-up of 44-100-44mm. Before quoting, dealers should confirm the quote stage package, layout, openings, selected wall or insulation scope, foundation interface, unloading access, EXW release or freight route from Kaunas, private-label documentation, and local-authority planning or site-use review requirements.
Warranty & Support
Product, order and after-sales conditions are confirmed in writing for each project in the quotation, order confirmation and applicable product documentation. Please contact Eurodita for the documentation relevant to your confirmed order. Detailed assembly documentation guides installation teams through construction stages. Technical support provides contractors with specification clarification and product data throughout the build process.
Trade pricing for verified B2B partners
Technical data sheet
Specification recorded for Eurodita Twin Skin four bed log cabin 16x9m. Dimensions are the building's external dimensions. A row appears only where a figure is recorded for this model.
| Building | |
|---|---|
| External dimensions | 16 x 9 m |
| Eaves height | 210 cm |
| Ridge height | 312 cm |
| Base | External footprint 16 x 9 m. Base type and size are confirmed for the specific model and site. |
| Structure | |
| Wall build-up | 44-100-44 mm: 44 mm outer skin, 100 mm cavity, 44 mm inner skin. 188 mm total wall thickness. |
| Other wall options | The other approved twin-skin build-ups and solid wall profiles can be specified to suit the project and budget. |
| Construction | Interlocking tongue and groove joints |
| Timber | Northern European timber |
| Storm brace and anchor set | Included |
| Floor | |
| Floor bearers | Impregnated as standard |
| Floor boards | 28 mm |
| Roof | |
| Roof boards | 19 mm tongue and groove boards |
| Doors and windows | |
| Doors | Double-Glazed Timber Joinery, Insulated Profile |
| Windows | Double-Glazed Timber Joinery, Insulated Profile |
| Scope of these figures | |
| Insulation | The 100 mm cavity is the space insulation occupies. Eurodita supplies the structure prepared for insulation, not the insulation material, so the cavity dimension is not an insulation specification. |
| Availability | Build-up availability and suitability for a given project and destination are confirmed per order. |
| Performance | These dimensions establish no thermal, fire, structural or certification performance. |
B2B Order Framework
Scope is confirmed in the written quotation and order documentation.
Private-label scope
Branding for packaging and relevant customer-facing documents is agreed per order.
Production planning
Production timing is confirmed in the written quotation and order acknowledgement for the selected model and specification.
Commercial terms
Price, quantity, payment and any volume conditions are quoted for the specific order.
Technical documents
The drawings, specifications and customer-facing documents included in the order are listed in the order documentation.
Configuration review
Dimensions, layout, openings, wall profile and other requested changes are reviewed before they are accepted into the quotation.
Dispatch terms
EXW Kaunas is the standard basis. Any delivered option is agreed for the specific market and order.
How a B2B Order Moves Forward

Specification
Share the model or drawing, destination, quantity and required configuration. Missing technical inputs are confirmed before quotation.

Manufacturing scope
Only the model, options, documentation and branding listed in the accepted order move into production.

Checking and packing
Completed order components are checked and packed against the agreed order scope before factory dispatch.

Dispatch terms
Orders are dispatched from Kaunas under the agreed collection or logistics terms. This does not promise carrier or final-mile delivery performance.