Eurodita Twin skin one bed log cabin 6x5m

The Twin Skin One Bed Log Cabin delivers project-specific accommodation within a compact 6x5m footprint. This insulated double-wall structure suits contractors developing project-specific accommodation solutions, glamping operators, and dealers and developers requiring garden accommodation concepts for local review.

Technical Specifications

Wall Thickness:
44-100-44
Construction:
Strong interlocking tongue & groove joints
External dimensions:
6 x 5m
Eaves Height (cm):
220
Ridge Height (cm):
247
Material:
Slow-grown northern European spruce
Doors:
Double-Glazed Timber Joinery, Insulated Profile
Windows:
Double-Glazed Timber Joinery, Insulated Profile
Floor Boards:
28mm
Floor Bearers:
Pressure-treated for longevity
Roof:
Tongue & groove boards: 19mm
Storm brace & anchor set:
Included
Anti Rot Warranty:
10 Year

Add-ons & Customisation

✅ Logo branding on drawings and packaging
✅ Wall thickness upgrade
✅ Roof & floor insulation
✅ Optional wall liner insulation
✅ Roof board 28 mm & rafter upgrade
✅ Project-specific glazing options
✅ Extra windows / repositioning / skylight
✅ Internal partitions + door kits
✅ Veranda/canopy/storage annex
✅ Production schedule review
✅ Dealer presentation support

Need this in a different size?

This model is supplied as a 6 x 5 m footprint. If your customer needs a different layout, send a drawing. Eurodita will confirm whether the qualified bespoke route and factory scope fit the exact project. Partner branding is agreed per order.

  1. 1 Send a drawing A hand sketch can start the review. Mark known window and door positions, wall thickness and heights; Eurodita confirms any missing technical inputs.
  2. 2 Confirm the quotation scope If the enquiry fits, pricing and any CAD/3D or technical material are prepared to the agreed scope.
  3. 3 Review the agreed scope Revisions follow the quotation and project scope until written sign-off.

CAD/3D quotation material is prepared to the qualified project scope. Availability and timing are confirmed during qualification. Partner branding is applied where agreed; required manufacturer, legal and traceability information is retained.

Send a bespoke brief

Dimensions, wall thickness and opening positions are confirmed per project at quote stage. Bespoke production timing is confirmed in the written quotation and order. See published projects for built examples with dimensions and drawings, or review the rest of the 1 bedroom log cabins range.

About This Eurodita Twin skin one bed log cabin 6x5m

Product Overview

The Twin Skin One Bed Log Cabin delivers project-specific accommodation within a compact 6x5m footprint. This insulated double-wall structure suits contractors developing project-specific accommodation solutions, glamping operators, and dealers and developers requiring garden accommodation concepts for local review. The twin-skin design supports project-specific seasonal-use brief when the build-up is confirmed at quote stage.

Layout & Configuration

The single-bedroom layout maximises internal floor area efficiency within the 30 square metre interior. Open-plan main room area connects seamlessly to the private bedroom compartment, while the 220cm eaves height and 247cm ridge create comfortable headroom throughout. Configuration allows for bathroom integration and kitchen installation to compact accommodation functionality.

Timber & Construction

Slow-grown northern European spruce forms the selected twin-skin wall build-up, incorporating insulation cavity between inner and outer log walls. Precision-cut interlocking tongue and groove joints ensure well-fitted construction, while double-glazed timber joinery provides insulation support. The insulated profile doors and windows maintain consistent insulation support across all openings.

Floor & Roof

The floor and roof specification uses 28mm pressure-treated floor boards mounted on engineered bearer system. The roof incorporates 19mm tongue and groove boarding with integrated storm bracing, with site-exposure details reviewed during project specification. This foundation-to-ridge construction approach is documented for dealer, installer and local-authority review where relevant.

Customisation Options

Wall thickness upgrades accommodate varying insulation requirements and local project requirements. Additional glazing configurations can be reviewed for colder-climate project briefs. Interior partition kits enable bathroom separation, while veranda extensions increase covered outdoor space. Insulation specifications adjust to meet specific insulation specification targets for different geographical markets.

Manufacturing & Delivery

Eurodita's Kaunas facility has up to 150,000 m³ of annual timber-processing capacity. Standard catalogue production is planned around the standard four-week cabin window; route-specific freight timing is confirmed per quote. Bespoke modifications accommodate specific site requirements and project documentation needs. Manufacturing capacity supports volume project planning for trade partners.

Private Label Partnership

Private-label manufacturing enables dealers to market under their own branding with customised documentation and specifications. Partner programmes include 3D visualisation support, branded assembly instructions, and showroom display coordination. Technical sales support assists with customer consultations and project specifications. Marketing materials adapt to partner brand guidelines and local market requirements.

Warranty & Support Eurodita provides 10-year anti-rot warranty documentation for eligible timber components, with scope, exclusions, treatment, installation and maintenance requirements confirmed in the order documentation.

What should dealers confirm before quoting Twin Skin one bed log cabin 6x5m?

Eurodita supplies Twin Skin one bed log cabin 6x5m through its private-label twin-skin cabin manufacturing, with a 6 x 5m footprint and selected twin-skin specification. Before quoting, dealers should confirm openings, selected twin-skin build-up, insulation scope, foundation interface, unloading access, EXW logistics route from Kaunas and local authority review requirements. See the twin-skin annexe specification route and EXW release and freight planning guidance before making client-facing commitments.

B2B Order Framework

Scope is confirmed in the written quotation and order documentation.

Private-label scope

Branding for packaging and relevant customer-facing documents is agreed per order.

Production planning

Production timing is confirmed in the written quotation and order acknowledgement for the selected model and specification.

Commercial terms

Price, quantity, payment and any volume conditions are quoted for the specific order.

Technical documents

The drawings, specifications and customer-facing documents included in the order are listed in the written quotation.

Configuration review

Dimensions, layout, openings, wall profile and other requested changes are reviewed before they are accepted into the quotation.

Dispatch terms

EXW Kaunas is the standard basis. Any delivered option is agreed for the specific market and order.

How a B2B Order Moves Forward

Specification

Specification

Share the model or drawing, destination, quantity and required configuration. Missing technical inputs are confirmed before quotation.

Manufacturing scope

Manufacturing scope

Only the model, options, documentation and branding listed in the accepted order move into production.

Checking and packing

Checking and packing

Completed order components are checked and packed against the agreed order scope before factory dispatch.

Dispatch terms

Dispatch terms

Orders are dispatched from Kaunas under the agreed collection or logistics terms. This does not promise carrier or final-mile delivery performance.

Scroll to Top