Log Cabin Axminster 5x5m, 44mm
Technical Specifications
Add-ons & Customisation
Need this in a different size?
This model is supplied as a 5 x 5 m footprint, 44 mm wall profile. If your customer needs a different layout, send a drawing. Eurodita will confirm whether the qualified bespoke route and factory scope fit the exact project. Partner branding is agreed per order.
- 1 Send a drawing A hand sketch can start the review. Mark known window and door positions, wall thickness and heights; Eurodita confirms any missing technical inputs.
- 2 Confirm the quotation scope If the enquiry fits, pricing and any CAD/3D or technical material are prepared to the agreed scope.
- 3 Review the agreed scope Revisions follow the quotation and project scope until written sign-off.
CAD/3D quotation material is prepared to the qualified project scope. Availability and timing are confirmed during qualification. Partner branding is applied where agreed; required manufacturer, legal and traceability information is retained.
Send a bespoke briefDimensions, wall thickness and opening positions are confirmed per project at quote stage. Bespoke production timing is confirmed in the written quotation and order. See published projects for built examples with dimensions and drawings, or review the rest of the garden log cabins range.
About This Log Cabin Axminster 5x5m, 44mm
Product Overview
The Axminster delivers a practical 5x5m footprint for garden project sites applications. This self-build log cabin suits contractors and developers requiring reliable outdoor workspace or leisure accommodation. The 44mm wall construction provides project-specific thermal specification while maintaining cost-effective installation for trade partners across European markets.
Layout & Configuration
The 25 square metre interior accommodates flexible room arrangements for diverse client requirements. Standard configuration incorporates double-glazed door and window units positioned for optimal natural light distribution. The 195cm eaves height supports comfortable headroom throughout, with 247cm ridge height creating generous internal volume for varied applications.
Timber & Construction
Slow-grown northern European spruce construction incorporates precision-milled 44mm thickness logs with engineered tongue-and-groove profiles. The interlocking joint system helps reduce thermal weak points while supporting assembly stability. Double-glazed timber joinery features standard profile design, delivering consistent weather-protection and thermal specification for extended-season or project-specific outdoor building performance.
Floor & Roof
The floor system incorporates 28mm tongue-and-groove boards supported by pressure-treated bearers for ground contact durability. Roof construction features 19mm tongue-and-groove boards providing weather-protected coverage. Storm bracing components support assembly stability under variable weather conditions, with final site suitability confirmed by the dealer or project team.
Customisation Options
Wall thickness upgrades accommodate enhanced insulation requirements for extended-season usage. Additional glazing configurations include triple-glazed units and alternative window positioning. Internal partition kits enable multi-room layouts, while veranda extensions expand outdoor coverage. Timber treatment options include coloured stains matching specific architectural requirements for dealer-led accommodation projects.
Manufacturing & Delivery
Manufactured at Eurodita's Kaunas facility, part of our 150,000 cubic metre annual production capacity established since 1994. Standard delivery timeframe spans four weeks across European markets. Our CNC machining capabilities enable bespoke dimensional modifications while maintaining consistent quality standards for trade partner requirements.
Private Label Partnership
Private-label manufacturing supports dealer branding with customised documentation and marketing materials. Comprehensive 3D visualisation tools assist customer presentation, while showroom display programmes enhance retail presence. Technical drawings and assembly guides incorporate partner branding for seamless customer experience across distribution channels.
What should dealers confirm before quoting Log Cabin Axminster 5x5m, 44mm?
Eurodita supplies Log Cabin Axminster 5x5m, 44mm as a private-label B2B garden cabin with a 5x5m footprint and 44mm slow-grown northern European spruce wall specification. Before quoting, dealers should confirm the quote stage package, wall profile, glazing/openings, roof and floor options, finish or treatment route, packaging, unloading access, EXW release or freight route from Kaunas, private-label documentation, and local-authority planning or site-use review requirements.
Warranty & Support Eurodita provides 10-year anti-rot warranty documentation for eligible timber components, with scope, exclusions, treatment, installation and maintenance requirements confirmed in the order documentation.
B2B Order Framework
Scope is confirmed in the written quotation and order documentation.
Private-label scope
Branding for packaging and relevant customer-facing documents is agreed per order.
Production planning
Production timing is confirmed in the written quotation and order acknowledgement for the selected model and specification.
Commercial terms
Price, quantity, payment and any volume conditions are quoted for the specific order.
Technical documents
The drawings, specifications and customer-facing documents included in the order are listed in the written quotation.
Configuration review
Dimensions, layout, openings, wall profile and other requested changes are reviewed before they are accepted into the quotation.
Dispatch terms
EXW Kaunas is the standard basis. Any delivered option is agreed for the specific market and order.
How a B2B Order Moves Forward

Specification
Share the model or drawing, destination, quantity and required configuration. Missing technical inputs are confirmed before quotation.

Manufacturing scope
Only the model, options, documentation and branding listed in the accepted order move into production.

Checking and packing
Completed order components are checked and packed against the agreed order scope before factory dispatch.

Dispatch terms
Orders are dispatched from Kaunas under the agreed collection or logistics terms. This does not promise carrier or final-mile delivery performance.